Frequency inverter in construction elevator solution

Construction elevator system Introduction
In the modern High-rise building construction, the construction elevator is the most important equipment which is used in big-scale tower crane.
Generally, the construction elevator can be divided into three kinds in speed, low-speed elevator in the speed range of 0~40m/min, medium-speed elevator in the speed range of 0~63m/min, high-speed elevator in the speed range of 0~96m/min.
The ordinary elevator is controlled by contactors, it has the disadvantage of:
(1) Single operation speed;
(2) Big surge current in start and stop;  
(3) Heavy damage for structure and mechanism system;
(4) The electric components are easily damaged;
(5) Running speed is always low, in the range of 34~38m/min.
This low-end system will reduce the construction speed and also reduce the benefit of enterprises. If we only increase the operation speed, the concussion of structure and mechanism will be enlarged and increase the abrasion between gear rack and brake disc accordingly, it will reduce the reliability of operation.
As the layers increase, for the building which the height is more than 400m, the high speed elevator of 96m/min will be used to increase the construction efficiency, It need very big braking resistance to consume the regenerated energy while the elevator going down. It has big security risk and energy losing in the application of long-term braking (length of 400m, braking period more than 5min).

Variable frequency adjustable speed system introduction
The whole system consists of PLC, frequency inverter, energy feedback system, electric motor, reduction box, AC input reactor, transformer, operation hand shank etc., to control the start, stop, up going, down going, brake and every kinds of protection of the elevator. The elevator will work at the condition of high-efficiency, safe and stable, meanwhile, the regenerated energy while the elevator going down will be fed back to the power grid to save energy.

frequency inverter in construction elevator

Advantage of the inverter solution
(1) High-efficiency, the running speed is as high as 60~70m/min which is double of traditional elevator(34 m/min);
(2) Energy feeds back to power grid, save considerable energy for customer, good braking effect;
(3) High output torque in low speed;
(4) Reduce the driving concussion of mechanism system effectively, prolong the working life of gear, contact roller, bearing and gear rack; The current limitation function of frequency inverter reduces the surge current while starting the motor, and also reduce the interference among the power consumption devices;
(5) The system has perfect safety protect functions such as under voltage, over voltage, over torque, over current and so on; it enhances the reliability and safety for the total system.
(6) The system adopts low-speed braking method, the small rotary friction force prolongs the working life of brake effectively.
(7) Compare with traditional non speed adjustable elevator, the comfortable feeling during operation is wonderful.

Other Applications:

Variable frequency drive for CNC machine solution Variable frequency drive for CNC machine solution The range of main spindle variable frequency variable speed is very wide, the VFD drive can achieve stepless speed regulation in the range of 0~300Hz, The variable frequency drive matches with CNC machine not only simplify complex mechanical drive mechanisms, such as gearbox, etc, but also make the operation easy & maintenance convenience;
Current vector AC drive for centrifugal dehydrator Current vector AC drive for centrifugal dehydrator AC Drive System Configurations
1. Open loop vector control AC drive
2. Current vector control feature
3. Choose braking resistor according the motor power
4. Braking unit is required if the power is more than 15kW
Variable Speed Drive for Sucker Rod Pumps Variable Speed Drive for Sucker Rod Pumps - The system in the multi-step speed control mode: two steps of high speed and low speed, the travel switches are fixed at the up-running end point and the down-running end point, the step speeds are changed by trigger the switches.
- The energy feedback unit is fixed to feed the regenerated energy back to the power grid.
- The function of the variable speed drive output relay terminal is set as failure warning output.